Building Management Systems
 |
Sauter novaPro Open System manages complex installations and system integration.
It has more than 100 drivers for linking to non-Sauter system with high level integration for linking to databases via ODBC, DDE, SQL and OPC etc.
novaPro Open provides an excellent window to makes information available locally or world via web technology.
Its scalability and modularity, can be adapted to any requirement of the plant or facility.
The extended alarm management facilities permit reporting of events via SMS, e-mail, fax or voicemail. With the integrated time planner, it can organise the duty personnel to be notified.
|
 |
|
 |
|
|
| |
|  |
Field Equipment
 |
Intelligent or stand-alone controllers and field equipment.
Comprehensive measurement and control technology from a single source.
|
 |
|
 |
|
|
| |
|  |
Valve & Acutator
 |
A complele family of valves and drives with SUT technology.
The SUT(Sauter Universal Technology) drives adapt themselves to the control system with inbuilt "Intelligence" and can determine the valves respective working stroke independently. This drive automatically ascertain whether a 3-point, 2-point or continuous signal is connected. The valve's running time and characteristic can be set individually.
|
 |
|
 |
|
|
| |
|  |
PharmaControls
 |
Laboratories are not places where you can afford to experiment with safety installation. Even the best ventilation and safety system concepts mean nothing without state-of-art components plus correct installation and implemention.
Sauter has the right system hardware installation experience for electronic, pneumatic, communicative or explosion protection environments.
Sauter extractors used in laboratories perform safely and meet all directives. Our pneumatic and electronic volume-flow controllers, drives, sash sensor, face velocity sensor and monitoring facilities meet the DIN12924(new EN14715) requirement.
|
 |
|
 |
|
|
| |
|  |
Complete range of VAV Air Terminal Box for Laboratory, Isolation Room and Fume-Hood controls
 |
Galvanise Sheet - Conform to corrosive class C3, EN-ISO12944-2. Leakage rate prEN 122-37 Class B with EPDM elastomer seal.
Stainless Steel(304) - Confrom to corrosive class C4, EN-ISO12944-2. Leakage rate prEN 122-37 Class B with EPDM elastomer seal.
Plastic(PP or PPS) - Leakage rate prEN 122-37 Class B with EPDM elastomer seal.
|
 |
 |
|
|
| |
|  |
Complete range of Venturi Valve with various material for Laboratory, Isolation Room and Fume-Hood Controls
 |
Aluminium valve with heresite coating.
304 stainless steel valve.
304 stainless steel valve with heresite coating.
304 stainless steel valve with Teflon coating.
316 stainless steel valve.
316 stainless steel valve with heresite coating.
316 stainless steel valve with Teflon coating.
|
 |
 |
|
|
| |
|  |
|